Heng's sideward flow paper

Draft #4 (version seen by referees) (.ps)
Referee reports
Response to referee reports
Draft #5 (30 March '00) (.ps)
For final version, see main page for E895 journal publications
Check status at PRL

Main supporting material
Extra material on deuteron contamination
New corrections for pion contamination
Page requested by Jim (method III vs IV)

Main USB page on proton flow at 6A GeV
Additional USB material (5 April '00)

In December 1999, we began to suspect (mistakenly, as it turns out) that there was a significant discrepancy in <px> between BTF and JTF. This prompted the tracker comparison by Paul and Roy (2nd last link above). The latter quotes a preliminary JTF flow calculated by Heng, which was amended later, and also quotes Heng's flow from his primary BTF analysis before his final correction for pion contamination. Also, there is a typo in the final table for the USB result based on BTF. The following table gives the best "final values" at 6A GeV beam energy for the slope F = d<px>/dy in MeV/c:
    JTF          BTF     
Heng     196     171
USB     200     186

Subsequently, Richard has carried out a slow simulator study which serves to confirm that (a) we need not be concerned about tracker differences in sideward flow analyses, and (b) the detector distortion using the py slice approach is within error bars for both trackers over the rapidity range of interest.